atacore error |
|
|
Nonii, kaks tutikat seagate 120GB pata ketast ja mõlemaga annab seatools floppi ver põhjaliku testi sees atacore error 2 ja 11 (logist näen, sest test ise jääb toppama). Mobo on i815 chipsetiga ja 60GB seagate ei karju. Win all online test ütleb OK ja midagi muud kahtlast pole tuvastanud. seatoolsi quick test on ka OK. Kaablid 80 soonega ja OK, toide chieftek, fsb 133 (proovin pärast ka 100MHz peal).
BIOS tunneb kettad ära 120GB, proovitud üksikult master ja teise kettaga slavena. Errorkoodide kohta infot ei leidnud ja mõne uuema moboga pole võimalust proovida - ise oletan, et asi on geomeetria tõlgendamises või midagi taolist, millega DOS modes võib kalasid olla.
Ideid-kogemusi?
_________________ M: APC Smart-UPS SC 1000VA 230V - 2U Rackmount/Tower, SC1000I. Musta värvi. Akudeta. 125EUR |
|
Kommentaarid: 359 loe/lisa |
Kasutajad arvavad: |
   |
:: |
0 :: |
3 :: |
276 |
|
tagasi üles |
|
 |
XYZ
HV Guru

liitunud: 05.11.2001
|
07.03.2005 16:11:26
Re: atacore error |
|
|
raamat kirjutas: |
Nonii, kaks tutikat seagate 120GB pata ketast ja mõlemaga annab seatools floppi ver põhjaliku testi sees atacore error 2 ja 11 (logist näen, sest test ise jääb toppama). Mobo on i815 chipsetiga ja 60GB seagate ei karju. Win all online test ütleb OK ja midagi muud kahtlast pole tuvastanud. seatoolsi quick test on ka OK. Kaablid 80 soonega ja OK, toide chieftek, fsb 133 (proovin pärast ka 100MHz peal).
BIOS tunneb kettad ära 120GB, proovitud üksikult master ja teise kettaga slavena. Errorkoodide kohta infot ei leidnud ja mõne uuema moboga pole võimalust proovida - ise oletan, et asi on geomeetria tõlgendamises või midagi taolist, millega DOS modes võib kalasid olla.
Ideid-kogemusi? |
Errorkoodid on Seagate kodulehel FAQ seas olemas ja :
"02 DST was Interrupted by Reset or Power Off"
"SMART error 0x11"
|
|
Kommentaarid: 81 loe/lisa |
Kasutajad arvavad: |
   |
:: |
3 :: |
12 :: |
56 |
|
tagasi üles |
|
 |
raamat
HV Guru

liitunud: 28.11.2002
|
07.03.2005 16:19:55
|
|
|
tsitaat: |
DiagATA and DiagSCSI Test Modules
Short Generic Test ATA SCSI
No error 0x10 0x30
SMART error 0x11 NA
Defective drive* 0x12 0x32
Run long generic test 0x13 0x33
Bad cable 0x14 0x34
Device not supported 0x15 0x35
Drive password protected 0x16 0x36
Shock damage 0x17 0x37
Corrupted format* NA 0x38
Long Generic Test ATA SCSI
No error 0x20 0x40
SMART error 0x21 NA
Defective drive* 0x22 0x42
Bad cable 0x24 0x44
Shock damage 0x27 0x47
Corrupted format* NA 0x48
Aborted 0x50 0x70
DST Error Codes
00 No Error
01 DST was Aborted by User
02 DST was Interrupted by Reset or Power Off
03 DST Could Not be Run
04 DST Failed for Reasons Unknown
05 DST Failed Electrical Element (Read/Write Head Check)
06 DST Failed Servo Element (Track Following Check)
07 DST Failed Read Element (A Bad Sector was Found)
* "Defective drive" and "Corrupted format" errors (sometimes called 03/31 errors) can often be repaired with a data-destructive zero fill data pattern or a low level format. Current disc drives contain thousands of spare sectors which are automatically reallocated if the drive senses difficulty reading or writing. Since SeaTools is read-only (data safe), occasionally a problem sector that has not reallocated to a spare sector can be forced to do so by writing to that sector. Spare sector reallocation is a normal intelligent drive operation.
|
OK, lasen Generic testiga üle ja vaatan, mis errorit siis annab.
_________________ M: APC Smart-UPS SC 1000VA 230V - 2U Rackmount/Tower, SC1000I. Musta värvi. Akudeta. 125EUR |
|
Kommentaarid: 359 loe/lisa |
Kasutajad arvavad: |
   |
:: |
0 :: |
3 :: |
276 |
|
tagasi üles |
|
 |
raamat
HV Guru

liitunud: 28.11.2002
|
14.03.2005 19:18:09
|
|
|
Nonii, ikkagi ei mingit selgust. Pistsin teise arvutisse - sama:
atacore error 2 in smartreaddata
atacore error 11 in smartreaddata
Keerasin biosest smart ning powersavingud maha - ikka sama lugu.
Jutt siis DST long testist, mitte generic testist. generic long test on OK.
Seatools disc diagnostic 1.04.03
_________________ M: APC Smart-UPS SC 1000VA 230V - 2U Rackmount/Tower, SC1000I. Musta värvi. Akudeta. 125EUR |
|
Kommentaarid: 359 loe/lisa |
Kasutajad arvavad: |
   |
:: |
0 :: |
3 :: |
276 |
|
tagasi üles |
|
 |
|
lisa lemmikuks |
|
|
sa ei või postitada uusi teemasid siia foorumisse sa ei või vastata selle foorumi teemadele sa ei või muuta oma postitusi selles foorumis sa ei või kustutada oma postitusi selles foorumis sa ei või vastata küsitlustele selles foorumis sa ei saa lisada manuseid selles foorumis sa võid manuseid alla laadida selles foorumis
|
|
Hinnavaatlus ei vastuta foorumis tehtud postituste eest.
|