truenas# smartctl -a /dev/sda1
smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.10.42+truenas] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke,
www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Crucial/Micron Client SSDs
Device Model: CT120BX500SSD1
Serial Number: 1921E1832DBF
LU WWN Device Id: 0 000000 000000000
Firmware Version: M6CR013
User Capacity: 120,034,123,776 bytes [120 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Form Factor: 2.5 inches
TRIM Command: Available, deterministic, zeroed
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-2 T13/2015-D revision 3
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Tue Aug 31 08:45:25 2021 EEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
See vendor-specific Attribute list for marginal Attributes.
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 120) seconds.
Offline data collection
capabilities: (0x11) SMART execute Offline immediate.
No Auto Offline data collection support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
No Selective Self-test supported.
SMART capabilities: (0x0002) Does not save SMART data before
entering power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 10) minutes.
SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x002f 100 100 050 Pre-fail Always - 0
5 Reallocate_NAND_Blk_Cnt 0x0032 100 100 010 Old_age Always - 0
9 Power_On_Hours 0x0032 100 100 050 Old_age Always - 16578
12 Power_Cycle_Count 0x0032 100 100 050 Old_age Always - 107
171 Program_Fail_Count 0x0032 100 100 050 Old_age Always - 0
172 Erase_Fail_Count 0x0032 100 100 050 Old_age Always - 0
173 Ave_Block-Erase_Count 0x0032 100 100 050 Old_age Always - 16
174 Unexpect_Power_Loss_Ct 0x0032 100 100 050 Old_age Always - 51
180 Unused_Reserve_NAND_Blk 0x0032 100 100 050 Old_age Always - 100
183 SATA_Interfac_Downshift 0x0032 100 100 050 Old_age Always - 0
184 Error_Correction_Count 0x0032 100 100 050 Old_age Always - 0
187 Reported_Uncorrect 0x0032 100 100 050 Old_age Always - 0
194 Temperature_Celsius 0x0022 067 048 050 Old_age Always In_the_past 33 (Min/Max 23/52)
196 Reallocated_Event_Count 0x0032 100 100 050 Old_age Always - 0
197 Current_Pending_ECC_Cnt 0x0032 100 100 050 Old_age Always - 0
198 Offline_Uncorrectable 0x0030 100 100 050 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x0032 100 100 050 Old_age Always - 0
202 Percent_Lifetime_Remain 0x0030 099 099 001 Old_age Offline - 99
206 Write_Error_Rate 0x002e 100 100 050 Old_age Always - 0
210 Success_RAIN_Recov_Cnt 0x0032 100 100 050 Old_age Always - 0
246 Total_LBAs_Written 0x0032 100 100 050 Old_age Always - 1097697107
247 Host_Program_Page_Count 0x0032 100 100 050 Old_age Always - 34303034
248 FTL_Program_Page_Count 0x0032 100 100 050 Old_age Always - 20385792
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended offline Completed without error 00% 16577 -
# 2 Extended offline Aborted by host 90% 15905 -
# 3 Short offline Completed without error 00% 14527 -
Selective Self-tests/Logging not supported
#
truenas# smartctl -a /dev/sdb1
smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.10.42+truenas] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke,
www.smartmontools.org
=== START OF INFORMATION SECTION ===
Device Model: WDC WD20EFZX-68AWUN0
Serial Number: WD-WX32DC0PDDVL
LU WWN Device Id: 5 0014ee 2be7fb176
Firmware Version: 81.00A81
User Capacity: 2,000,398,934,016 bytes [2.00 TB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 5400 rpm
Form Factor: 3.5 inches
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: ACS-3 T13/2161-D revision 5
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Tue Aug 31 08:51:53 2021 EEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: (23220) seconds.
Offline data collection
capabilities: (0x11) SMART execute Offline immediate.
No Auto Offline data collection support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
No Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 249) minutes.
SCT capabilities: (0x303d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always - 0
3 Spin_Up_Time 0x0027 196 196 021 Pre-fail Always - 3158
4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 8
5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0
7 Seek_Error_Rate 0x002e 200 200 000 Old_age Always - 0
9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 285
10 Spin_Retry_Count 0x0032 100 253 000 Old_age Always - 0
11 Calibration_Retry_Count 0x0032 100 253 000 Old_age Always - 0
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 7
192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 0
193 Load_Cycle_Count 0x0032 200 200 000 Old_age Always - 8
194 Temperature_Celsius 0x0022 121 109 000 Old_age Always - 26
196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0
197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 0
198 Offline_Uncorrectable 0x0030 100 253 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0
200 Multi_Zone_Error_Rate 0x0008 100 253 000 Old_age Offline - 0
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
No self-tests have been logged. [To run self-tests, use: smartctl -t]
Selective Self-tests/Logging not supported
#